{"product_id":"biomedical-bc_biomedical_esu-2300","title":"ESU-2300 ESU Analyzer","description":"\u003cdiv aria-expanded=\"true\" aria-hidden=\"false\" aria-labelledby=\"ui-id-2\" class=\"ui-tabs-panel ui-widget-content ui-corner-bottom\" id=\"descPane\" role=\"tabpanel\"\u003e\n\u003cdiv id=\"ctl00_ctl00_NestedMaster_PageContent_ctl00_ProductDescription1_DescriptionAjax\"\u003e\n\u003cdiv class=\"widget productDescription\"\u003e\n\u003cdiv class=\"innerSection\"\u003e\n\u003cdiv class=\"header\"\u003e\n\u003ch2\u003e\n                        Description \n                        \u003ca href=\"javascript:__doPostBack('ctl00$ctl00$NestedMaster$PageContent$ctl00$ProductDescription1$More','')\" id=\"ctl00_ctl00_NestedMaster_PageContent_ctl00_ProductDescription1_More\"\u003emore details\u003c\/a\u003e\n\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"content\"\u003e\n\u003cdiv class=\"descriptionWrapper\" itemprop=\"description\"\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003eThe ESU-2300 is an Electrosurgical Analyzer. The “measurement engine” of the ESU-2300 is a specially-engineered true-RMS RF ammeter and wattmeter, designed to measure the complex RF waveforms produced by electrosurgical generators. The ESU-2300 has been designed to comply with electrosurgical manufacturer industry standard current sensing technology and utilizes an internal precision RF Current Transformer. The analyzer utilizes a precision internal test load resistor network. The ESU-2300 is intended to be routinely used to measure the various parameters relating to the testing and performance validation of electrosurgical generators.  DFA\u003cspan style=\"position: relative; top: -3pt;\"\u003e®\u003c\/span\u003e Technology allows the ESU-2300 to aggressively digitize the complex electrosurgical generator waveform, analyze its components and provide accurate and stable results. It may be used as a stand-alone meter or in conjunction with a PC utilizing the optional software. \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"margin: 0in 0in 0pt; text-align: justify;\"\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv class=\"pageHeader\"\u003e\u003cstrong\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"color: #000000;\"\u003eProduct Highlights\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan style=\"color: #000000;\"\u003e:\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eTrue RMS readings using patent pending DFA® technology\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eIndustry standard current sensing technology\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003emV, mV peak, crest factor and power (wattage) ranges\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eRF current (mA) and power (watts) can be displayed\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eInternal precision load resistor network: 50 ohms to 750 ohms in 50 ohm increments External load \u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003eresistor capability – uses the external resistor value as a discrete value or add it to any internal\u003c\/span\u003e\u003c\/span\u003e \u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003eload resistor value\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003e2.5% of reading accuracy on RF current (mA)\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003e5% of reading accuracy on RF power (watts)\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eInternal load resistor network is cooled with temperature and power controlled cooling fan\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eUses an internal 0.1:1 ratio precision RF current transformer\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eIndependent CQM (REM\/ARM) resistor network: 1 ohm to 500 ohms in 1 ohm increments\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eRF leakage measurements through 200 W test load\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eInternal rechargeable battery allows operation independent of line power\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eLarge graphics display with cursor selection of options and setup of parameters\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eDigital data output via USB\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eRemote capabilities using RS-232 and USB\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003ePC based interface program optional\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eDigital calibration – no pots to turn\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eSelectable display options\u003c\/span\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan style=\"font-family: Arial;\"\u003e\u003cspan style=\"font-size: small;\"\u003e\u003cspan\u003e• \u003c\/span\u003eTactile keys with audio feedback\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"customFieldsWrapper\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PM BioMedical","offers":[{"title":"Default Title","offer_id":52564691288380,"sku":"ESU-2300","price":6649.18,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0914\/6839\/8908\/files\/img_6945226412e745.78945537_1766138468.png?v=1766143563","url":"https:\/\/pmbiomedical.com\/products\/biomedical-bc_biomedical_esu-2300","provider":"PM BioMedical","version":"1.0","type":"link"}